Factory Real Photos

Oil-Resistant Rubber Hose
The oil-resistant rubber hose is a rubber hose specifically designed for transferring oil-based media and for long-term use in oily environments. Made with oil-resistant rubber compounds, it resists swelling, hardening, or cracking when exposed to mineral oil, hydraulic oil, fuel, lubricating oil, and similar media. It is widely used in automotive, construction machinery, industrial equipment, hydraulic systems, and other fields.
Rubber Crossing Panels for Rail Vibration Isolation
Disclaimer: All typical values are obtained under standard laboratory or factory test conditions for reference only. Actual performance is subject to panel model, installation quality, ballast condition, axle load, traffic speed and end-use environment. Request formal test reports and project-specific engineering evaluation before final selection.
Product Features
·Excellent Oil Resistance: Resistant to mineral oil, hydraulic oil, fuel, lubricating oil, etc., with minimal swelling, deformation, or cracking.
·Safe Transfer: Reliable sealing prevents oil leakage, ensuring system and personnel safety.
·Stable Pressure Resistance: Can be designed with braided or spiral reinforcement to withstand medium and high-pressure conditions.
·Durable & Long-Lasting: Resistant to aging, wear, and high/low temperatures, extending service life.
·Broad Compatibility: Multiple materials, structures, and specifications are available to cover oil transfer needs across industries.
Advantages
1. Leak-proof & burst-resistant, ensures operational safety
2. Wear/chemical-resistant, long service life
3. Flexible, easy to install in tight spaces
![]() |
![]() |
Product Specifications
1. Rail Types / Panel Models
|
Model |
Rail Profile |
Rail Gauge |
Sleeper Type |
|
P43 |
43 kg/m rail |
1435 mm (standard gauge) |
Wooden or concrete sleepers |
|
P50 |
50 kg/m rail |
1435 mm (standard gauge) |
Wooden or concrete sleepers |
|
P60 |
60 kg/m rail |
1435 mm (standard gauge) |
Concrete sleepers (heavy haul) |
|
Custom |
Other rail profiles (UIC50, UIC60, 50N, 60N) |
Custom gauge on request |
Other sleeper types on request |
Panel set per crossing:
1 inner panel (between two rails) + 2 outer panels (outside each rail)
Optional 4-panel set for wider road crossings
2. Size and Weight Table P50 rail (50 kg/m)
|
Position |
Length (mm) |
Width (mm) |
Height (mm) |
Weight (kg/panel) |
|
Inner panel (between rails) |
1100 / 1650 / 2200 |
750 |
175 |
200 |
|
Outer panel (each side) |
1100 / 1650 / 2200 |
480 |
145 |
100 |
P60 rail (60 kg/m)
|
Position |
Length (mm) |
Width (mm) |
Height (mm) |
Weight (kg/panel) |
|
Inner panel (between rails) |
1100 / 1650 / 2200 |
750 |
202 |
250 |
|
Outer panel (each side) |
1100 / 1650 / 2200 |
490 |
160 |
140 |
P43 rail (43 kg/m)
|
Position |
Length (mm) |
Width (mm) |
Height (mm) |
Weight (kg/panel) |
|
Inner panel (between rails) |
1100 / 1650 / 2200 |
750 |
175 |
200 |
|
Outer panel (each side) |
1100 / 1650 / 2200 |
480 |
145 |
100 |
Standard panel length: 1.1 m (for manual handling), 1.65 m and 2.2 m (for faster installation).
Custom lengths and widths available on request.
3. Design Load / Capacity
3.1 Railway Load (Rail Wheel Load)
|
Parameter |
Value |
Remarks |
|
Design axle load (mainline) |
Up to 25 t / axle |
Standard mainline railway |
|
Design axle load (heavy haul) |
Up to 30–40 t / axle |
Mining / heavy-haul lines |
|
Design train speed |
Up to 80 km/h |
Higher speeds available upon engineering evaluation |
|
Load verification |
1.5 × design axle load |
Static load test, no visible crack or rupture |
|
Safety factor |
≥ 3 × design axle load |
Ultimate load test on batch samples |
3.2 Road Vehicle Load (Road Traffic)
|
Parameter |
Value |
Remarks |
|
Road load class |
Highway Grade I / II (China) or equivalent |
Depends on crossing location and traffic volume |
|
Single wheel load (road) |
Up to 60 kN |
Typical heavy vehicle wheel load |
|
Skid resistance |
R13 class or project-specified |
Surface texture designed for wet and dry conditions |
|
Pedestrian loading |
5 kN/m² |
For station platforms and walkways |
4. Test Reports and Quality Inspection
4.1 Routine Factory Tests (Per Batch)
|
Test Item |
Test Method |
Acceptance Criteria |
|
Hardness |
ASTM D2240 / GB/T 531.1 |
Within specified range |
|
Tensile strength |
ASTM D412 / GB/T 528 |
≥ 13 MPa |
|
Elongation at break |
ASTM D412 / GB/T 528 |
≥ 350% |
|
Compression set |
ASTM D395 Method B |
≤ 25% |
|
Low-temperature brittleness |
ASTM D2137 / GB/T 15256 |
No failure at -40 °C |
|
Ozone ageing resistance |
ASTM D1149 |
No visible cracking |
|
Load compression |
ASTM D575 / GB/T 7757 |
Permanent set ≤ 5% under rated axle load |
4.2 Type-Approval Tests (Project-Specific)
|
Test Item |
Test Method |
Acceptance Criteria |
|
Static load test |
EN 13146-4 / TB/T 3395.4 |
1.5 × design axle load, no crack or rupture |
|
Fatigue test |
EN 13146-4 / TB/T 3395.4 |
450,000 load cycles (simulated train passages) at design axle load, no failure |
|
Abrasion resistance |
Taber / DIN 53516 |
Volume loss within specified limit |
|
Weathering / UV ageing |
ISO 4892-2 / ASTM G154 |
1000 h exposure, no significant degradation |
|
Fire resistance |
UL 94 / ASTM D635 |
Optional, project-specific |
|
Electrical insulation |
IEC 62631 / GB/T 1410 |
Volume resistivity ≥ 10⁹ Ω·cm (for insulated versions) |
Installation Drawings and Application Cases
5. Installation Drawings and Application Cases
5.1 Typical Installation Layout
- Panels laid between rails (inner panel) and outside rails (outer panels)
- Secured to sleepers with screw spikes (wooden sleepers) or embedded anchor bolts (concrete sleepers)
- Panels interlock with tongue-and-groove joints to prevent shifting
- Gap between rail base and panel filled with flexible sealant to prevent ballast fouling
- Rail web / foot contact area sealed with elastomeric profile to prevent water ingress and ballast migration
- Road surface flush with rail top edge for smooth vehicle transition
5.2 Installation Steps
- Remove existing old crossing material and clean ballast
- Inspect and repair sleeper condition; replace damaged sleepers if necessary
- Place inner panel between rails, align with sleeper anchors
- Place outer panels on each side
- Fasten with provided clips / bolts to sleepers
- Apply flexible sealant at rail-panel interface and panel joints
- Check surface flushness; adjust shim if needed
- Torque all fasteners to specified value; re-check after first week of traffic
- Conduct periodic inspection of fastener tightness and panel seating
5.3 Application Cases
- Mainline railway level crossings (road-rail intersections)
- Urban light rail / tram line crossings
- Industrial sidings, factory spurs, port railways
- Station platforms, pedestrian walkways, freight yards
- Maintenance depots and workshop tracks
- Mining and forestry railway crossings
![]() |
![]() |
4SP / 4SH Common Specifications and Performance
4SP / 4SH Common Specifications and Performance | ||
Characteristics |
4SP |
4SH |
Standard |
EN 856 4SP |
EN 856 4SH |
Corresponding SAE |
Approx. 100R12 |
Approx. 100R13 |
Structure |
4-layer high-strength spiral wire |
4-layer high-strength spiral wire |
Inner Tube |
Oil-resistant synthetic rubber |
Oil-resistant synthetic rubber |
Cover |
Weather and abrasion resistant synthetic rubber |
Weather and abrasion resistant synthetic rubber |
Temperature Range |
-40°C to +100°C |
-40°C to +100°C (some up to +121°C) |
Fluid Compatibility |
Mineral oil, glycol, water-oil emulsion, water (0–70°C) |
Same as left |
Impulse Requirement |
≥400,000 cycles @133% WP, 100°C |
≥400,000 cycles @133% WP, 100°C |
Customization Service
Customized inner diameter, outer diameter, length, wall thickness, pressure rating, fittings, and packaging according to customer drawings or samples.
R&D Centre - Laboratory

GET IN TOUCH
Please fill in your question and we will reply you as soon as possible.