Leave Your Message
Oil Pipes with Enhanced Pulse Resistance
OTHER

Oil Pipes with Enhanced Pulse Resistance

A critical fluid transfer component designed for high-pressure oil systems, ensuring safe, leak-free oil delivery in industrial/automotive setups.

    manufacturing-standards

    Factory Real Photos

    软管

    Oil-Resistant Rubber Hose

    The oil-resistant rubber hose is a rubber hose specifically designed for transferring oil-based media and for long-term use in oily environments. Made with oil-resistant rubber compounds, it resists swelling, hardening, or cracking when exposed to mineral oil, hydraulic oil, fuel, lubricating oil, and similar media. It is widely used in automotive, construction machinery, industrial equipment, hydraulic systems, and other fields.

    Rubber Crossing Panels for Rail Vibration Isolation

    Disclaimer: All typical values are obtained under standard laboratory or factory test conditions for reference only. Actual performance is subject to panel model, installation quality, ballast condition, axle load, traffic speed and end-use environment. Request formal test reports and project-specific engineering evaluation before final selection.

    Product Features

    ·Excellent Oil Resistance: Resistant to mineral oil, hydraulic oil, fuel, lubricating oil, etc., with minimal swelling, deformation, or cracking.

    ·Safe Transfer: Reliable sealing prevents oil leakage, ensuring system and personnel safety.

    ·Stable Pressure Resistance: Can be designed with braided or spiral reinforcement to withstand medium and high-pressure conditions.

    ·Durable & Long-Lasting: Resistant to aging, wear, and high/low temperatures, extending service life.

    ·Broad Compatibility: Multiple materials, structures, and specifications are available to cover oil transfer needs across industries.

    Advantages

    1. Leak-proof & burst-resistant, ensures operational safety

    2. Wear/chemical-resistant, long service life

    3. Flexible, easy to install in tight spaces

    image-2 image-3

    Product Specifications

    1. Rail Types / Panel Models

    Model

    Rail Profile

    Rail Gauge

    Sleeper Type

    P43

    43 kg/m rail

    1435 mm (standard gauge)

    Wooden or concrete sleepers

    P50

    50 kg/m rail

    1435 mm (standard gauge)

    Wooden or concrete sleepers

    P60

    60 kg/m rail

    1435 mm (standard gauge)

    Concrete sleepers (heavy haul)

    Custom

    Other rail profiles (UIC50, UIC60, 50N, 60N)

    Custom gauge on request

    Other sleeper types on request

    Panel set per crossing:

    1 inner panel (between two rails) + 2 outer panels (outside each rail)

    Optional 4-panel set for wider road crossings

    2. Size and Weight Table P50 rail (50 kg/m)

    Position

    Length (mm)

    Width (mm)

    Height (mm)

    Weight (kg/panel)

    Inner panel (between rails)

    1100 / 1650 / 2200

    750

    175

    200

    Outer panel (each side)

    1100 / 1650 / 2200

    480

    145

    100

    P60 rail (60 kg/m)

    Position

    Length (mm)

    Width (mm)

    Height (mm)

    Weight (kg/panel)

    Inner panel (between rails)

    1100 / 1650 / 2200

    750

    202

    250

    Outer panel (each side)

    1100 / 1650 / 2200

    490

    160

    140

    P43 rail (43 kg/m)

    Position

    Length (mm)

    Width (mm)

    Height (mm)

    Weight (kg/panel)

    Inner panel (between rails)

    1100 / 1650 / 2200

    750

    175

    200

    Outer panel (each side)

    1100 / 1650 / 2200

    480

    145

    100

    Standard panel length: 1.1 m (for manual handling), 1.65 m and 2.2 m (for faster installation).
    Custom lengths and widths available on request.

    3. Design Load / Capacity

    3.1 Railway Load (Rail Wheel Load)

    Parameter

    Value

    Remarks

    Design axle load (mainline)

    Up to 25 t / axle

    Standard mainline railway

    Design axle load (heavy haul)

    Up to 30–40 t / axle

    Mining / heavy-haul lines

    Design train speed

    Up to 80 km/h

    Higher speeds available upon engineering evaluation

    Load verification

    1.5 × design axle load

    Static load test, no visible crack or rupture

    Safety factor

    ≥ 3 × design axle load

    Ultimate load test on batch samples

    3.2 Road Vehicle Load (Road Traffic)

    Parameter

    Value

    Remarks

    Road load class

    Highway Grade I / II (China) or equivalent

    Depends on crossing location and traffic volume

    Single wheel load (road)

    Up to 60 kN

    Typical heavy vehicle wheel load

    Skid resistance

    R13 class or project-specified

    Surface texture designed for wet and dry conditions

    Pedestrian loading

    5 kN/m²

    For station platforms and walkways

    4. Test Reports and Quality Inspection

    4.1 Routine Factory Tests (Per Batch)

    Test Item

    Test Method

    Acceptance Criteria

    Hardness

    ASTM D2240 / GB/T 531.1

    Within specified range

    Tensile strength

    ASTM D412 / GB/T 528

    ≥ 13 MPa

    Elongation at break

    ASTM D412 / GB/T 528

    ≥ 350%

    Compression set

    ASTM D395 Method B

    ≤ 25%

    Low-temperature brittleness

    ASTM D2137 / GB/T 15256

    No failure at -40 °C

    Ozone ageing resistance

    ASTM D1149

    No visible cracking

    Load compression

    ASTM D575 / GB/T 7757

    Permanent set ≤ 5% under rated axle load

    4.2 Type-Approval Tests (Project-Specific)

    Test Item

    Test Method

    Acceptance Criteria

    Static load test

    EN 13146-4 / TB/T 3395.4

    1.5 × design axle load, no crack or rupture

    Fatigue test

    EN 13146-4 / TB/T 3395.4

    450,000 load cycles (simulated train passages) at design axle load, no failure

    Abrasion resistance

    Taber / DIN 53516

    Volume loss within specified limit

    Weathering / UV ageing

    ISO 4892-2 / ASTM G154

    1000 h exposure, no significant degradation

    Fire resistance

    UL 94 / ASTM D635

    Optional, project-specific

    Electrical insulation

    IEC 62631 / GB/T 1410

    Volume resistivity ≥ 10⁹ Ω·cm (for insulated versions)

    Installation Drawings and Application Cases

    5. Installation Drawings and Application Cases

    5.1 Typical Installation Layout

    • Panels laid between rails (inner panel) and outside rails (outer panels)
    • Secured to sleepers with screw spikes (wooden sleepers) or embedded anchor bolts (concrete sleepers)
    • Panels interlock with tongue-and-groove joints to prevent shifting
    • Gap between rail base and panel filled with flexible sealant to prevent ballast fouling
    • Rail web / foot contact area sealed with elastomeric profile to prevent water ingress and ballast migration
    • Road surface flush with rail top edge for smooth vehicle transition

    5.2 Installation Steps

    1. Remove existing old crossing material and clean ballast
    2. Inspect and repair sleeper condition; replace damaged sleepers if necessary
    3. Place inner panel between rails, align with sleeper anchors
    4. Place outer panels on each side
    5. Fasten with provided clips / bolts to sleepers
    6. Apply flexible sealant at rail-panel interface and panel joints
    7. Check surface flushness; adjust shim if needed
    8. Torque all fasteners to specified value; re-check after first week of traffic
    9. Conduct periodic inspection of fastener tightness and panel seating

    5.3 Application Cases

    • Mainline railway level crossings (road-rail intersections)
    • Urban light rail / tram line crossings
    • Industrial sidings, factory spurs, port railways
    • Station platforms, pedestrian walkways, freight yards
    • Maintenance depots and workshop tracks
    • Mining and forestry railway crossings

     

    image image-1

     

    4SP / 4SH Common Specifications and Performance

    4SP / 4SH Common Specifications and Performance

    Characteristics

    4SP

    4SH

    Standard

    EN 856 4SP

    EN 856 4SH

    Corresponding SAE

    Approx. 100R12

    Approx. 100R13

    Structure

    4-layer high-strength spiral wire

    4-layer high-strength spiral wire

    Inner Tube

    Oil-resistant synthetic rubber

    Oil-resistant synthetic rubber

    Cover

    Weather and abrasion resistant synthetic rubber

    Weather and abrasion resistant synthetic rubber

    Temperature Range

    -40°C to +100°C

    -40°C to +100°C (some up to +121°C)

    Fluid Compatibility

    Mineral oil, glycol, water-oil emulsion, water (0–70°C)

    Same as left

    Impulse Requirement

    ≥400,000 cycles @133% WP, 100°C

    ≥400,000 cycles @133% WP, 100°C

    Optional Materials:
    NBR, HNBR, FKM, CR (Neoprene), etc.

    Customization Service

    Customized inner diameter, outer diameter, length, wall thickness, pressure rating, fittings, and packaging according to customer drawings or samples.

    R&D Centre - Laboratory


    R&D Centre - Laboratory

    GET IN TOUCH

    Please fill in your question and we will reply you as soon as possible.

    description2